Install Instructions For Englander Vacuum Switch (OEM): PU-VS
To change out a Vacuum Switch for 2006 and later
models, simply perform the following steps:
1. First, remove the rear access panel from your unit;
this may be done using a 5/16" socket or wrench .
2. Examine the labels on each of the Vacuum Switches
that are fastened to the stove. Be sure you are replacing
the correct switch. .04 or .17
3. Remove the two screws that fasten the switch that
needs to be replaced. Remove the Vacuum Hose from
the switch, and also remove the two wires that are
attached to the switch.
Read More...
In most cases the switch is going to be fine. to test it you need to attach a meter to the 1-3 positions of the switch and apply suction the the hose attached to the gray side of the switch. WATCH OUR VIDEO for a full explanation.